Code Requirements for Retaining Wall Drainage
Feb 23, 2024 · At 11 courses of 8-inch blocks, the wall is 7'-4" high. Is the soil on the high side fairly close to the elevation of the top of the wall? Any retaining wall that retains more than 4 feet of earth …
Retaining Wall Guard Requirement - The Building Code Forum
Nov 22, 2021 · 7. was the 48" retaining wall permitted under the building code or just built under a zoning requirement? After the homeowner/builder unlawfully excavated, the city directed him to build …
Retaining wall footing - The Building Code Forum
May 23, 2014 · A wall not laterally supported at the top, that resists lateral soil load and other imposed loads. In my opinion the language, as written, does not specifically require professional engineering …
Retaining wall question - The Building Code Forum
Jul 27, 2012 · The picture is of a "natural" retaining wall. (the wall is 12' at the highest point) It was built during the construction of the house which is under permit but it is not connected to the house, nor …
Retaining wall codes - The Building Code Forum
Jul 8, 2022 · The wall is 31" away from the driveway, but is over a 6-foot drop. I can't find any details about the code for retaining walls. Is the builder required to have a barrier - natural or manmade? A …
Retaining Wall Guard Requirement | Page 2 | The Building Code Forum
Oct 22, 2009 · Retaining walls with a difference in finished grade from the top of the wall to the bottom of the wall that is greater than 4 feet (1219 mm) shall be provided with guards complying with Sections …
Retaining Wall Drop-Off Fencing - The Building Code Forum
May 20, 2017 · Hello! I'm having a new construction home built in Lake Stevens, Wa and there is a retaining wall around my lot that results in a 3' drop-off around my back yard. I was wondering if there …
Retaining Wall - The Building Code Forum
Sep 27, 2012 · Depending on how the retaining wall affects the (future) building, it may not be a building codes factor. Doesn't help you today, but maybe the 'administration' could include the retaining wall …
Understanding FEMA's V Zone Construction Certification Requirements
Oct 16, 2009 · Professionals involved in V Zone construction should consult local authorities for specific certification requirements. Additional Certifications: Breakaway Wall Design: Must be certified by a …
6 foot high Concrete block wall without embedded foundation or footing
Nov 24, 2019 · The 6 foot concrete wall was built on the property line in 2010. The owner called it a retaining wall when I asked what he was doing. That required a 5 foot set back and a footing …